It is possible for the software raid to get into a degraded state. Replace c0 with the appropriate number in the examples below. Raid rebuild steps for 3ware 9550sx and similar spiceworks. Find answers to 3ware raid degraded raid 5 from the expert community at.
This article will outline some common causes and methods for rebuilding the raid volumes. It can be used for all maintenance operations that can be performed through the 3dmd daemon or the system bios. When the 3ware card sees the new drives, it will add them as individual onedrive jbod units. For brevity, we will only consider a raid 1 setup but the concepts and commands apply to all cases alike. Windows xp, 2000, server 2003, windows x64bit, linux and freebsd. To force the rebuild to start, go to the managementscheduling page of 3dm2. For lsi 3ware controllers, use the management software 3dm2 cli from the latest available code set, e. Select the raid disk and the new disk, then select rebuild. I reseated the raid controller which fixed the issue. This is a common problem with raid5 a failure on a second disk whilst rebuilding the array.
This set is the data repository for our primary sql server, so i am being overly cautious. This morning i came in the office to discover that two of the drives on a raid6, 3ware 9650se controller were marked as degraded and it was rebuilding the array. The following additional documenta tion is available for your 3ware raid controller on the cd that came with your controller. Im using the lsi 3ware 9650se with windows 10 x64 pro with no issues. Sata plus sas raid controller card familty, software. Getting started 2 3ware 9690sa sassata raid controller installation guide this document, 3ware 9690sa sassata raid controller installation guide 3ware cdrom with driver, software, and additional documentation appropriate cables for your 3ware 9690sa model. On the linked provider page, simply search for cli and select software on the search results page the help command returns all available commands. Diskinternals raid recovery reconstructs all types of arrays. Driver installation under red hat linux or fedora core 5. After getting to about 4%, it got ecc errors on a third drive this may have happened when i attempted to access the filesystem on this raid and got io errors from the controller.
What i am missing a practical procedure for doing the actual replacement and rebuild. With the new drive attached, the 3ware bios does not install and it says that the unit is offline. The 9000 series from 3wareamcc has now been available for a few months. By clicking accept, you understand that we use cookies to improve your experience on our website.
Moreover, it show rebuild status in percent when the array is rebuilding and its easily parsable because 3ware filled the not relevant columns with a dash instead of leting them empty. This document, 3ware serial ata raid controller user guide, provides instructions for. The 3ware controllers do not start a rebuild immediately after a system is booted in order to give the operating system and applications time to load. Installing windows server 2008 r2 server with 3ware 9650se. It provides controller, logical unit and drive management. Once the machine boots up, the array should rebuild itself after about 10 minutes. Jul 10, 2015 this however leaves raid header info on the cold drive, so next time you hotswap the disk, the raidcontroller wont touch your disk. Keep an eye on this and monitor the rebuild process. If you pick up a sata2 hard drive, set the speed to sata 1 seagate uses a jumper, hitachi has a software tool, etc. The driver im using is from 21420 downloaded from lsi avago.
It differs from its sata competitors in that it has a hardware xor. Raid recovery 2019, raid 0 6 data recovery diskinternals. Trying to rebuild an array that has a degraded drive wont fix it if the drive has. If your hwraid system is an unique snowflake, you need to plan an exit strategy in case your raid controller becomes unusable and cant be replaced. The 3ware software cdrom that came with the 3ware raid controller includes compiled and tested drivers for freebsd 4. Aug 31, 2004 the 9000 series from 3ware amcc has now been available for a few months. Tips on working with 3ware raid controllers 3ware raid controllers are dependable, reliable controllers, capable of decent throughput, which are supported by many versions of linixi. The raid should start to rebuild itself, but may delay the start for upwards of 10 minutes. Rebuild processes for raid 10 will begin at 50% there you have it you have now replaced the bad drive and it is just a matter of time until it rebuilds. It is a raid monitoring utility which help to maintain the 3ware raid array.
Another essential feature in it environments is the ability for the 3ware 9650se card to automatically rebuild the raid array if a drive fails. However, i was seeing a disk degraded when looking at the raid controller management software 3dm2 firstly i sshd into the openfiler server. Last but not least, the 9650se supports a variety of operating systems including the following. This morning i came in the office to discover that two of the drives on a raid 6, 3ware 9650se controller were marked as degraded and it was rebuilding the array.
This says do rebuild on adapter 0 a0 doing a rebuildarray on channel 0 disk 2 0. Cancelling a rebuild and restarting it with a different drive. Raid support the lsi 3ware 97508i supports multilevel raid configuration including raid 0, 1, 5, 6, 10 and 50 for better performance, enhanced data security and flexible capacity upgrades. Line interface storage management software for 3ware ata raid controllers. Hi all, i am replacting a disk in my raid 4 array and it is not progressing from 0% it has been sitting like this for 2 hour now. This however leaves raid header info on the cold drive, so next time you hotswap the disk, the raid controller wont touch your disk. Firstly, our new dell 1950s are great servers and i really love the build quality and design thought that has gone into them. It was part of a linux software raid 1 mirrored drives, so we lost no data, and just needed to replace hardware. How to install 3ware raid controller management vmware.
A hardware array would usually automatically rebuild upon drive replacement, but this needed some help. Since it believes that the disk is part of another raid set. After the rebuild completes your raid 1 parity will be back to normal. All i want to do is to be able to install software onto the server so that in the event of a diskraid failure, we get an email. Hardwareraid uberwachen wiederaufbauen windows ionos. Sorry, i did not intend my earlier comment as a chastisement, but more to raise awareness of the trap of using hardware raid in smallscale. I have dealt with other raid controllers, and disk replacements rebuilds and have a suited understanding on the general practice, as well as the 3ware lsi cli reference handy.
It is a command line interface storage management software for amcc 3ware ata raid controllers. Configure the new raid card lsi megaraid 92718i on a ds diacap recorder. This time, select the ignore source errors setting. Rebuilding raid after degraded disk using 3dm2 management. Feb 10, 2014 i need some direction on a replacement rebuild process for a disk in a mirrored set using a 3ware lsi 9650se2lp controller. We can use this t o check the health of my 3ware raid array under any linux distribution we can either run it as as program with its own command line. Is there any software or instructions out there on how to get data off of a 3ware raid set using raid5 when the controller doesnt function. Oct 06, 2015 recover rebuild failed software raids part 8 in this guide we will discuss how to rebuild a software raid array without data loss when in the event of a disk failure. Combined with an advanced raid management feature set that includes webbased, commandbased, and api software components, the 9550sx, available highlights in 4, 8, 12, and 16port configurations, is the most compelling solution available. Once it is complete it should return into ok status. Raid array recovery software for nvidia, intel, via. Nov 27, 2014 press alt3 to bring up the 3ware bios utility.
How to recover data and rebuild failed software raids part 8. First, a foreign configuration usually refers to a raid configuration that already exists on a replacement set of drives that you install in a computer system. Dssrv dssrv2 raid status and drive failures lsi 3ware 9750 raid original number of views 4. I ended up using reclaime file recovery that you can download here paired with reclaime free raid recovery to scanrebuild the raid parameters you can get here. Press f8 to save the changes and continue with booting. Rebuilding raid after degraded disk using 3dm2 management cli. Whoever set this up as a raid 5 with a spare it isnt setup properly, either wasnt the brightest. This however leaves raid header info on the cold drive, so next time you hotswap the disk, the raidcontroller wont touch your disk. The program developed by 3ware for the administration of the raid controller can be found in. View and download lsi 3ware 9750 user manual online. Basically youre in the instance where a raid 10 can only lose 1 drive, because it always depends on which disks go bad. It is only available on your 3ware cd, in the doc3warehtmlbookshelf folder. As the card doesnt support raid 6, we cant use that recommended for large drives, so well have to go with raid 10. It is a raid monitoring utility which help to maintain the 3ware raid array we can use this tocheck the health of my 3ware raid array under any linux distribution.
Hardwareraid uberwachen wiederaufbauen linux ionos hilfe. Connect the drive to the controller and boot the machine. Recreate with raid 10, create the partitions, formatmount and update etcfstab. The logs files showed that there was a drive error. It is a command line interface storage management software for amcc3ware ata raid controllers. Oct 01, 2018 when any of the software raids enter a degraded state an alert is shown in the user interface as well as emailed in the daily status email. It differs from its sata competitors in that it has a hardware xor unit, plus the attractive storswitch architecture. If you need to install microsoft windows server 2008 r2 on a server with a 3ware 9650se raidcontroller, you cant just install it on this machine, you cant even install it with adding the driver during the installation process first update the raid controller firmware by downloading the codeset iso from the 3ware download page updated version 9. It also can be difficult to find a reliable, clear, and straight forward article about how the process is done.
448 639 1023 923 246 101 1352 927 1077 1628 858 242 401 165 275 1190 432 800 1334 1202 1346 1077 1019 847 1271 1633 659 1562 655 1446 901 863 1114 450 1218 881 1124 78 1471 368 293 857 1132